• IEC60112 Flammability Testing Equipment Determination of CTI and Pti PLC Control
  • IEC60112 Flammability Testing Equipment Determination of CTI and Pti PLC Control
  • IEC60112 Flammability Testing Equipment Determination of CTI and Pti PLC Control

IEC60112 Flammability Testing Equipment Determination of CTI and Pti PLC Control

After-sales Service: Available
Warranty: 1 Year
Max Diameter of Workpiece: 1800mm
Mass Scope of Workpiece: 6000kg
Type: Leakage Tracking Tester
Maxcapacity: >1000KN
Customization:
Diamond Member Since 2024

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Chinese
to see all verified strength labels (18)

Basic Info.

Model NO.
LT-3
Accuracy Grade
1.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
500-1000Kg
Power Source
AC380V
Oil Cylinder Position
Under
Control Mode of Operation
LC Control, 7 Inch Color Touch Screen Operation
7/5000 Electrode Pressure on The Test O
1.00n*0.05n
Transport Package
Plywood
Specification
1100*550*1200mm
Trademark
H&H
Origin
China
Production Capacity
10 Set Per Month

Product Description

IEC60112 Flammability Testing Equipment Determination Of CTI And PTI PLC Control
IEC60112 Flammability Testing Equipment Determination of CTI and Pti PLC Control

Standard:

IEC60112-2009 Method for the determination of the proof and the comparative tracking indices of solid insulating materials.

It specifies the method of test for the determination of the proof and comparative tracking indices of solid insulating materials on pieces taken from parts of equipment and on plaques of material using alternating voltages. Flammability Testing Equipment

 

Proof tracking index (PTI)

Where, in IEC standards for material or for electrical equipment specifications, or in other standards, a proof test only is required, 50 drop tests shall be made in accordance with Clause 8 but at the single voltage specified. The required number of specimens shall withstand the test period up to at least 25 s after the fiftieth drop has fallen without tracking failure, and without a persistent flame occurring.

Operation of the over-current device by air arcs does not constitute a tracking failure.

The proof voltage shall be an integer multiple of 25 V.

Comparative tracking index (CTI)

Determination of the comparative tracking index requires the determination of the maximum voltage at which five specimens withstand the test period for 50 drops without failure and whether, at a voltage of 25 V lower than the maximum 50 drop figure, the specimen withstands 1 00 drops. If this is not the case, the maximum 1 00 drop withstand voltage has to be determined.

 

Parameter:

Model LT-2(0.5m³) LT-3(0.5m³) (Touch screen)
Working voltage 220V/50Hz, 1KVA 220V/50Hz, 1KVA
Control operation mode Electrical control, button operation PLC control, 7 inch color touch screen operation, with infrared remote control
Testing voltage 0-600V adjustable, precision 1.5%
Timing device 9999X0.1S. Flammability Testing Equipment
Electrodes Material: Platinum electrode and brass connecting rod
The two electrodes shall have a rectangular cross-section of (5 ± 0,1 ) mm × (2 ± 0,1 ) mm, with one end chisel-edged with an angle of 30° ± 2° (see Figure 1 ). The sharp edge shall be removed to produce an approximately flat surface, 0,01 mm to 0,1 mm wide
Relative position of electrode Included angle: 60°±5°, distance is 4±0.1mm
Electrode pressure 1.00N±0.05N 1.00N±0.05N, Touch screen display
Dripping liquid The interval time of dropping liquid: 30±5S, digital display, can be preset
Height: 35±5mm
The number of drips:0-9999 times, can be preset, the volume size of the dripping liquid is controlled by the imported micro pump within 50 ~ 45 drips /cm³
Test solutions Solution A: 0.1%NH4Cl, 3.95±0.05Ωm, Solution B: 0.1%NH4Cl + 0.5± 0.002% sodium-di-butyl naphthalene sulfonate, 1.98±0.05Ωm
Time-delay circuit 2±0.1S (in 0.5A or larger current)
Short-circuit pressure drop 1±0.1A 1%, pressure drop 8% MAX
Wind speed 0.2m/s.
Environmental requirement 0~40ºC, relative humidity≤80%, in the place of no obvious vibration and corrosive gas
Dimensions and weight WDH=1100×550×1200 mm, 130kg WDH=1100×550×1200 mm, 130kg
 

We have other Flammability Testing Equipment Available. Needle-Flame Test Apparatus in IEC 60695-11-5, Horizontal-vertical Flame Test Apparatus in IEC 60695-11-3 and IEC 60695-11-4, Glow-Wire Test Apparatus in IEC60695-2-10, IEC60695-2-11, IEC60695-2-12 and IEC60695-2-13 and etc. Please refer to the Test Equipment List for Flammability Testing Equip...for our full equipment list of Flammability Testing Equipment.

IEC60112 Flammability Testing Equipment Determination of CTI and Pti PLC Control

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now