The storage water heater electrical performance test equipment laboratory manufactured by our company is an advanced system specially used for comprehensive and accurate detection and evaluation of the electrical performance of storage water heaters. It adopts the latest detection technology and high-precision measuring instruments, aiming to provide reliable performance testing solutions for water heater manufacturers, quality inspection institutions and related research units.
Electrical safety performance test
Leakage current detection: Accurately measure the leakage current of the water heater during operation to ensure the personal safety of the user.
Ground resistance test: Detect whether the grounding system of the water heater meets the safety standards and ensure the reliability of grounding.
Insulation resistance measurement: Evaluate the insulation performance of the electrical components of the water heater to prevent electrical short circuits and electric shock accidents.
Energy efficiency performance test
Heating efficiency determination: Accurately calculate the efficiency of the water heater in converting electrical energy into thermal energy, and provide data support for energy saving evaluation.
Insulation performance test: Monitor the water temperature changes of the water heater in different time periods and evaluate its insulation effect.
Working performance test
Water temperature control accuracy test: Check the control accuracy of the water heater on the water temperature to meet the user's demand for water temperature.
Hot water output measurement: Determine the amount of hot water that the water heater can provide per unit time.
Environmental adaptability test
High and low temperature environment simulation: Examine the working performance and reliability of the water heater under extreme temperature conditions.
Humidity adaptability test: Evaluate the operating status of the water heater in different humidity environments.
Standard:
IEC 60379 Methods for measuring the performance of electric storage water-heaters for household purposes.
GB 21519 Minimum allowable values of energy efficiency and energy efficiency grades for electrical storage water heaters.
Equipment system composition:
Test room: The test room has strict temperature and humidity requirements and is realized by computer room air conditioner.
Sample mounting bracket: 2pcs, installed in the test room, arranged on both sides, each test bracket has 3 test stations.
Water supply room: include 2 water storage tanks, and constant temperature and constant pressure water supply line pipe.
Control cabinet: It is the data collection, data processing and control center of the system. Appliance Performance Test Lab
Mounting of the water-heater:
Wall-mounted water-heaters are mounted on a panel situated at least 150 mm from any structural wall.
They are positioned so that there is a clear space of at least 250 mm above and below the heater and at least 700 mm at the sides and front.
Floor-mounted water-heaters are placed on the floor or on any stand supplied with them. A false floor may be used to facilitate measurements.
Water-heaters for building-in are built in according to the manufacturer's instructions.
Test room size | 6000*4000*2600mm |
Test room temperature | 20 ± 2 °C |
Test room humidity | <85% |
Sample mounting bracket | 2PCS |
Test station | 6 stations |
Water tank | 2PCS |
Water temperature range | 10-65 °C |
Water supply line pipe | 2 channels |
Water pressure range | 0.1-0.5Mpa. |