  • Overview
  • Product Description
  • Test items
  • Test object
  • Product Parameters
Overview

Basic Info.

Model NO.
RCMC007
Trademark
HJ
Origin
China
Production Capacity
3 Sets Per Month

Product Description

Ultra-low temperature refrigerant charging machine

Product Description

The refrigeration temperature of ultra-low temperature refrigerants can reach below -80°C. It is mainly used in ultra-low temperature equipment such as environmental test chambers, ultra-low temperature freezers, and blood bank refrigerators. R170 and R508b are currently the mainstream ultra-low temperature environmentally friendly refrigerants. Due to the low critical temperature of ultra-low temperature refrigerant, its charging mode is different from that of conventional refrigerants. With years of technology accumulation and continuous breakthroughs and innovations, HJ took the lead in launching an ultra-low temperature refrigerant filling machine with a filling accuracy of 100g≤±1g, which greatly improved Improved filling accuracy.

Test items

Filling accuracy detection:
Verify the filling accuracy of the filling machine under ultra-low temperature conditions to ensure that the refrigerant filling amount meets the preset standards.
Through multiple repeated tests, the stability and consistency of filling accuracy are evaluated.

Refrigeration performance testing:
Test the refrigeration effect of the filling machine in ultra-low temperature environment, including refrigeration speed, temperature stability, etc.
Verify that the filling machine is able to fill the refrigerant to the target temperature within the specified time.

Electrical safety testing:
Check whether the electrical system of the filling machine complies with relevant safety standards, including protective measures against electric shock and fire.
Conduct voltage and insulation tests on electrical components to ensure the reliability of the electrical system.

Explosion-proof performance testing:
Given that ultra-low temperature refrigerants may have flammable or explosive properties, it is crucial to test the explosion-proof performance of the filling machine.
Conduct explosion-proof testing to verify the safety of the filling machine in potentially explosive environments.

Mechanical performance testing:
Evaluate the mechanical structural strength and stability of the filling machine, including the wear resistance and corrosion resistance of key components.
The moving parts of the dispensing machine are tested for flexibility and reliability.

Environmental suitability testing:
Test the working performance of the filling machine under different environmental conditions, such as temperature, humidity, vibration, etc.
Verify that the filling machine can work properly in harsh environments.

Operational performance testing:
Evaluate the convenience of operation and the friendliness of the human-machine interface of the filling machine.
Test the filling machine's control system to ensure it responds quickly and accurately.

Leak detection:
Check whether there is refrigerant leakage during the filling process of the filling machine.
Use leakage detection equipment to conduct a comprehensive inspection of the filling machine to ensure that no leakage occurs.
 
Test object

Complete ultra-low temperature refrigerant filling machine:
Test the performance, function and safety of the complete filling machine to verify whether it meets the design requirements and usage standards.

Filling system components:
Including key components such as filling pumps, meters, valves, and sensors. The performance of these components directly affects the filling accuracy and stability of the filling machine.

Control system and electrical components:
Test the logic, response speed and accuracy of the control system, as well as the reliability and safety of electrical components.

Safety protection device:
Test the functions and performance of safety devices such as overload protection, pressure protection, and temperature protection to ensure that they can act in time under abnormal conditions to protect equipment and personnel.

Connection and compatibility with refrigeration systems:
Test the sealing and compatibility of the connection interface, pipes and other parts between the filling machine and the refrigeration system to ensure that the refrigerant can be filled into the refrigeration system smoothly and safely.

Accessories and Accessories:
Including filling guns, pipes, joints and other accessories, test whether their quality and performance meet the requirements.
 
Product Parameters

 

Model RCMC007
Charging gas R170, R508b and other ultra-low temperature refrigerants
Charging dose (g) 10-999
Charging speed (g/s) 1~10
Charging precision Within 100g≤±1g Above 100g≤±1%
Pumping speed 8L/S (optional)
Voltage & Power AC380V 50Hz 2kW (optional)
Volume & Weight L980*W800*H1650 390KG
 