Customization: | Available |
---|---|
Cooling Method: | Indirect Cooling |
Certification: | ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The refrigerant recovery machine can recover HCFC and HFC series mainstream refrigerants such as R22, R134a, R410A, R407C, etc. The recovery speed range is 25-90 kg/hour. The operation of the touch screen and PLC control system is used to achieve intelligent control. All parameters can be set on the touch screen. When the recycling is abnormal, an audible and visual alarm will be issued and the specific reason will be displayed. The refrigerant recovery machine uses a high-efficiency compressor, and both liquid and gaseous refrigerants can be quickly recovered with a recovery rate of ≥95%.
Recycling efficiency and performance testing:
Test the recovery efficiency of the refrigerant recovery machine under different conditions, including recovery speed, recovery volume, etc., to evaluate its performance.Refrigerant recovery machine body:
The refrigerant recovery machine itself is the object that needs to be comprehensively tested, including tests on its performance, efficiency, safety, stability, etc. These tests are designed to ensure that the refrigerant recovery machine can effectively recover refrigerant according to the design requirements while ensuring the safety and stability of the operation.
Ancillary equipment and accessories:
The refrigerant recovery machine is usually used with some ancillary equipment and accessories, such as pipes, valves, sensors, etc. The performance and quality of these equipment and accessories will also affect the effectiveness and safety of refrigerant recovery and therefore also need to be tested.
Different types of refrigerants:
The refrigerant recovery machine needs to be able to recover many different types of refrigerants, such as R22, R134a, R410A, etc. During the testing process, these different models of refrigerants need to be tested to ensure that the refrigerant recovery machine can adapt to and effectively recover various refrigerants.
Working environment and conditions:
The working environment of the refrigerant recovery machine is also an important object of testing. Under different conditions such as temperature, humidity, pressure, etc., the performance of the refrigerant recovery machine may be different. Therefore, the refrigerant recovery machine needs to be tested in various actual working environments to evaluate its adaptability and stability.
Model | RCM0009-A | RCM0009-S |
Recovery refrigerants | R134a,R404A,R406A,R22,R407C,R410A | |
Compressor power | Equivalent to 1.5HP | Equivalent to 5HP |
Recovery speed | 15-60 KG/H | 90-200 KG/H |
Power | 220V/50Hz | 220V/50Hz |
Interim cylinder | 40L/60L/100L interim cylinder optional | |
Recover rate | ≥95% | |
Recovery state | Gas, liquid |