• IEC60068 Programmable Constant Temperature and Humidity Box
  • IEC60068 Programmable Constant Temperature and Humidity Box
  • IEC60068 Programmable Constant Temperature and Humidity Box
  • IEC60068 Programmable Constant Temperature and Humidity Box
  • IEC60068 Programmable Constant Temperature and Humidity Box
  • IEC60068 Programmable Constant Temperature and Humidity Box

IEC60068 Programmable Constant Temperature and Humidity Box

After-sales Service: Yes
Warranty: One Year
Application: Industry, Lab
Customized: Customized
Certification: IEC
Structure: Large Box
Customization:
Diamond Member Since 2024

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Chinese
to see all verified strength labels (18)

Basic Info.

Model NO.
HH0811
Material
Alloy
Type
Constant Temperature and Humidity Test
Humidity Range
20%~98%Rh
Temperature Departure
Plus or Minus 2 Degrees Celsius
Temperature Uniformity
Plus or Minus 2 Degrees Celsius
Transport Package
Plywood
Specification
1200mm*2035mm*2050mm
Trademark
HJ
Origin
China
Production Capacity
10 Sets Per Month

Product Description

IEC60068 Programmable constant temperature and humidity box

Product introduction:
Programmable constant temperature and humidity chamber, also known as constant temperature and humidity testing machine, high and low temperature humidity and heat test chamber, and humidity and heat test chamber, is an environmental test chamber suitable for high and low temperature and humidity and heat testing of electrical, electronic and other products, components and materials. The equipment can meet the environmental tests of electrical and electronic products - high temperature test/low temperature test/high and low temperature cycle test/temperature change test/damp heat test/constant damp heat test/alternating damp heat test.


IEC60068 Programmable Constant Temperature and Humidity Box

Testing standards:
GB/T 2423.1-2008 Environmental testing of electrical and electronic products Part 2: Test methods Test A: Low temperature (IEC60068-2-1:2007, IDT);
GB/T 2423.2-2008 Environmental testing of electrical and electronic products Part 2: Test methods Test B: High temperature (IEC60068-2-2:2007, IDT);


Test object:
It provides virtual space to simulate real environments for aerospace, aviation, electronics, automobiles, batteries and other products and quality inspection institutes, research institutes, universities and other testing units to verify product inspection and R&D results. The test chamber shortens the development cycle. An indispensable assistant to improve product quality and reliability.


IEC60068 Programmable Constant Temperature and Humidity Box

Technical Parameters:
Project Parameter
Temperature range

A:-20~+150ºC

B:-40~+150ºC

C:-70~+150ºC

Humidity range 20%~98%RH
Temperature departure ±2ºC
Temperature uniformity ±2ºC
Temperature fluctuation ±0.5ºC
Humidity deviation ±3.0%RH(>75%RH);±5.0%RH(≤75%RH)
Humidity uniformity ± 3.0% RH (no load)
Humidity fluctuation ±2.5%RH(no load)
Power supply 220V±10%V/ 380V±10%V;50Hz;

IEC60068 Programmable Constant Temperature and Humidity Box


Q&A:
Q1: How to operate the programmable constant temperature and humidity test chamber?
A1: Operating a programmable constant temperature and humidity test chamber usually includes the following steps:

Open the main switch.
According to the experimental needs, check and adjust the water level of the water tank (if it is a humidity experiment), or take out the wet ball gauze (if it is only a high temperature experiment).
When placing the sample, pay attention to maintaining a certain distance between the sample and the box to prevent the sample from being too dense and affecting the air flow.
Turn on the power switch on the instrument panel.
Adjust or set the required temperature and humidity parameters through the touch screen.
During the experiment, do not open the door unless necessary. If you need to observe, you can use lights.
After the experiment is completed, turn off the power of the instrument and the main switch, and ensure that the temperature has cooled to a safe range before opening the door to take out the sample.
Q2: How to maintain the programmable constant temperature and humidity test chamber?
A2: The maintenance of programmable constant temperature and humidity test chamber includes:

The storage environment should be maintained between 5 and 35 degrees, with good ventilation and humidity below 85%.
Check the wet bulb water level regularly to ensure the accuracy of the water level remains within a certain range.
Regularly check and clean the humidification system, including pipes, humidification barrels, water cups and water tanks, using pure or filtered tap water.
The terminal blocks of electrical components should be tightened regularly and by persons with common knowledge as electricians.
Regularly clean the inside and outside of the test box, including the water bottle, the box, the power distribution room and the outside of the box.
Regularly check the refrigeration system pipelines to ensure that the valves are normal and leak-free.
Q3: What are the common faults of programmable constant temperature and humidity test chamber and how to solve them?
A3: Common faults and solutions include:

Panel over-temperature alarm: The compressor may be overloaded due to unstable voltage and current. It is recommended to shut down the machine and wait for the voltage to stabilize before turning it on again.
Heating tube heating alarm: This may require professional after-sales engineers to judge and solve.
Compressor overload alarm: usually occurs when there is water shortage. Check whether the water adding parts are leaking and repair or replace them in time.