Product Introduction of Helium Leak Testing Equipment:
This product is a power battery helium detector, which mainly includes battery scanning code, loading, leakage detection, evacuation, helium filling, helium inspection, and other processes. Then the helium signal in the leak detection chamber is detected by the helium leak detector, which can judge the leakage of the workpiece quickly and accurately with high precision. The equipment can be compatible with different sizes, but the fixture needs to be replaced.
Power battery helium sealing testing equipment is mainly used to test the helium sealing performance of power battery modules, packaging and related components. Here are some possible tests:
Leak test: Use helium as the detection gas to detect leaks in the battery packaging by creating a pressure difference. Air leak testing can use different methods, such as negative pressure, positive pressure or differential pressure.
Quantitative gas leakage detection: Evaluate the helium sealing performance of battery packaging by measuring the gas leakage rate or amount.
Gas permeability test: Use helium gas to perform a permeability test on the battery package to detect possible micropores or permeability defects in the battery package.
Packaging joint sealing test: Sealing performance test of battery connectors, sealing gaskets and other components to ensure the airtightness between the battery module and the external environment.
Air tightness visual inspection: Use helium to fill the battery package, and determine the location of the leak by detecting changes in helium concentration around the leak point.
Technical parameters of Helium Leak Testing Equipment:
NO. | Project | Parameter |
1 | Alarm leakage rate | 5E-5 mbar.l/sec |
2 | Energy consumption | 15KW |
3 | Vacuum chamber | 1 set |
4 | Production speed | 5min/ piece |
5 | Minimum detection accuracy | 1.0E-7mbar*L/S |
6 | Helium-filled pressure | 0-0.5Mpa |
7 | Size | ≤2500mm*2500mm*2200mm |
8 | Weight | 1000KG |
9 | Operating voltage | 380V |